Industrial LIFTRONIC AIR CEILING-RAIL 250 Product Specifications

  • Industrial
  • Orange
  • New
  • Easy To Operate Rust Proof
  • Electric
  • 110-415 Volt (v)

Industrial LIFTRONIC AIR CEILING-RAIL 250 Trade Information

  • 100 Piece Per Month
  • 7 Days

Product Description

Specification

Model

 

LA250 STD

 

LA250 L

 

Type

 

LA250

LA250+(4)

LA250L

LA250L+(4)

SQ(1) (Max Load capacity)

kg

 250

300

150

180

Min Load capacity

 kg

15

15

 15

 15

L1

mm

1565

1565

 1965

1965

L2

 mm

1040

1040

1535

1535

R1

mm

2605

2605

3500

3500

R2

mm

1109

1109

1263

1263

RH

mm

-

 960

 -

960

A(2)

mm

4172

4172

4492

4492

B(2)

mm

1536

1536

1656

1656

C(2)

mm

480

480

 600

600

D Vertical stroke

mm

1451

1451

1866

1866

E(2)

mm

2007

2007

2020

2020

Weight (with column and load)

 kg

723

900

661

837

Fv max(3)

daN

829

1030

758

960

Mges max(3)

daNm

1317

1300

1290

1300

  GENERAL TECHNICAL SPECIFICATIONS

  • Air pressure 0,65 MPa (6,5 bar) 
  • Power supply 115/230V A/C 50/60Hz
  • Power consumption 100VA
  • Enclosure protection IP54
  • Noise level < 70 dB(A)
  • Lifting capacity limiter
  • Lift speed from 15 to 30 m/min
  • Main column axis brake
  • Intermediate joint axis brake
  • Column rotation 360
  • Tool axis rotation 550
  • Slow descent in case of pressure failure
  • Balancing type: load preset or self balancing (it depends from the tooling)
Applicable standards:
  • Essential safety requirements provided by Directive 2006/42/EC;
  • Electrical Equipment - Electromagnetic Compatibility (EMC) Directive 2014/30/EU.
AVAILABLE OPTIONS
  • Brake for up/down movement
  • Special painting
  • Sliding trolley
  • Limit switch for the main and intermediate joint axis
WORKING ENVIRONMENT CONDITIONS
  • Relative humidity rate: 30% to 90% +/- 5%
  • Working temperature 5 to 50 C